Chat with us, powered by LiveChat Skip to content

Kvaser Memorator Professional HS/LS

SKU #: KV-00417-7
Save 6%
Original price $1,690
Current price $1,590

This product is EOL as of Jan 2023. Please consider the Kvaser Memorator Pro 2xHS V2 as the recommended replacement.

The Kvaser Memorator Professional is a small, yet advanced portable CAN data logger which can also be used as a CAN bus interface. The device can be configured in many different ways to achieve the most suitable and effective logging for any occasion. This product version offers one high-speed CAN channel and one low-speed CAN port.

Kvaser’s Memorator Professional contains an advanced set of features including Message Filtering, Error Detection Mode, Triggers, Battery Backup, an expandable SD Card slot, Linx J1587 compatible, Auto Transmit, Galvanic Isolation among other. Connecting the logger to a PC provides direct access for configuring baud rates, trigger conditions and filters using the standalone Kvaser Memorator Tools

Kvaser Memorator Professional Functions:

Triggers

Kvaser Memorator can log continuously, or logging can be triggered by external triggers (rising or falling edge) and/or by messages and signals on the CAN bus (triggered by identifier, or data contents.) Pre- and post-triggers are available.

Filters

To enhance logging performance, Kvaser Memorator can filter out selectable messages to be logged. The identifiers can be picked from a database, or all messages can be logged.

Memory cards

Standard MMC or SD type flash memory cards can be used. Larger memory cards, up to 1 GB, can be used. See our support pages for more information.

Configuration software in the PC:

  • Configuration of the CAN controller, i.e. bit rate and filters.
  • Configuration of the trigger conditions.
  • Configuration of filter for messages to be stored.
  • Configuration upload and download via USB.
  • One device for desktop and laptop
  • Quick and easy plug-and-play installation
  • Supports both 11-bit (CAN 2.0A) and 29-bit (CAN 2.0B active) identifiers
  • CAN messages are time-stamped with 10 microseconds resolution
  • Large on-board RAM buffer for CAN messages
  • Supports "listen-only" mode for bus analysis tools
  • Driver support for major operating systems
  • 100% compatible with applications written for Leaf, LAPcan, PCIcan, PCcan and USBcan with Kvaser's CANlib
  • One SD/MMC connector that accepts SD or MMC flash disks, currently up to 1 GB
  • One CAN connection ISO-11898 high-speed, 50kbit/s up to 1 Mbit/s (Philips TJA1050)
  • Optional, second CAN connection that can be either high-speed (TJA1050), low-speed (Philips TJA1054), or single-wire (AU5790)
  • One USB 1.1 connection (12 Mbit/s); this connection is compatible with USB 2.0
  • Power from CAN bus or from the USB side
  • Built-in real time (calendar) clock with battery backup
  • Logger status is indicated with four externally visible LEDs
  • Plastic housing with dimension WLH about 509025 mm (circa 2 x 3,5 x 1 inch)
Property Value
The information herein is subject to change without notice.
Galvanic Isolation No
Bitrate 10-1000 kbit/s
Silent mode Yes
Error frame generation Yes
Error frame detection Yes
Weight 150 grams
Timestamp resolution 30
On board buffer Yes
Maximum message rate, send 6000
Maximum message rate, receive 12000
Sound No
Clock synchronization N/A
Dimensions (WxLxH) 50x90x25 mm (2.0x3.5x1.0in.)
Getting Started Kvaser Memorator / Memorator Professional as Datalogger
Startup Guide Getting Started Kvaser Memorator /Memorator Professional as Datalogger
Version 2.0.0
Kvaser Database Editor Users Guide
Kvaser Database Editor Users Guide
Version 2.0.0
Kvaser Memorator Tools Introduction
Introduction to Kvaser Memorator Tools for Kvaser Memorator Professional
Version 1.0.0
Kvaser Memorator Professional Trigger Guide
Kvaser Memorator Tools - Trigger Guide
Version 2.0.0
Kvaser Memorator Professional Users Guide
Kvaser Memorator Professional User's Guide
Version 10.0.0
Trigger Kit for the Kvaser Memorator Family
Trigger Kit for the Kvaser Memorator Family
Version 2.0.0
Kvaser DIADEM Driver
This free driver for National Instrument's DIAdem supports all CAN hardware from Kvaser.
Version 1.0.0
Kvaser Drivers for Windows
Windows drivers for all our CAN hardware. Please check release notes for information on which Windows versions are supported. It also contain a driver for the virtual CAN bus.
Version 5.6.0
Kvaser Memorator Firmware
Driver removal program. This program will remove the CAN driver (version 3.9 or older) from your computer. This program will not work with driver 4.0 or later. Use it only if you need to remove an old version of the driver from your computer.
Version 3.9c
Kvaser Firmware Update Tool
Firmware Update tool for most Kvaser devices.
Version V4.24.477
Kvaser Database Editor
Standalone installer for Kvaser Database Editor.
Version 2.4.109
Kvaser Memorator Tools
Logger setup and configuration program for Kvaser Memorator Professional, Kvaser Memorator and Kvaser Memorator Light.
Version 3.7.537
Kvaser CANKing
A free of charge general-purpose CAN bus momnitor. Works with all CAN interfaces from Kvaser. Windows 200 and later recommended.
Version 5.3.889
Kvaser CANlib SDK
Software development kit - everything you need to develop software for the Kvaser CAN and LIN interfaces. Link libraries, header files, sample programs, Microsoft Visual Basic and Borland Delphi components, documentation, and more. Note: you need to download and install the appropriate device drivers separately
Version 5.6.0
Kvaser LabView VI Library for CAN
Library for National Instrument's LabView version for all Kvaser CAN hardware.
Version 6.1.0
Kvaser Linux Driver and SDK
Linux driver and SDK for Kvaser PCIcan/PCIcanx, Kvaser PCIcanII, Kvaser PC104+, Kvaser PCIcanx II, Kvaser USBcan II, Kvaser Memorator*, Kvaser Leaf family, Kvaser Memorator Pro**, Kvaser USBcan Pro and VirtualCAN. For LAPcan and LAPcan II, you should use version 4.2 of the driver. (*) only with USBcanII functionality, (**) only with USBcan Pro functionality
Version 5.3.0
Remove old drivers
Driver removal program. This program will remove the CAN driver (version 3.2 or older) from your computer. This is a version intended for those who have installed CANLIB 3.2 or older. Use it only if you need to remove an old version of the driver from your computer. Contact technical support if you have any questions.
Version 3.9c
Cleanup
Driver removal program. This program will remove the CAN driver (version 3.9 or older) from your computer. This program will not work with driver 4.0 or later. Use it only if you need to remove an old version of the driver from your computer.
Version 3.9c
This product is EOL as of Jan 2023. Please consider the Kvaser Memorator Pro 2xHS V2 as the recommended replacement. The Kvaser Memorator Professional is a small, yet advanced portable CAN data log...